Prepare two ITS and two 16S PCR plates for the following template plates:

4AH1

4AH2

4PA1

4PA2

4PA3

4PA4

4PA5

4PA6

4MR1

4MR2

4SC1

4SC2

4LVD1

4LVD2

4LVD3

4FB1

4FB2

4FB3

MasterMix (make for 16 plates in 50mL conical tube)

ul/rxn

Reagent

# of rxns

ul needed

3

5X Kapa HiFi Buffer

1700

5100

0.45

10M dNTPs

1700

765

0.3

Kapa HiFi HotStart DNA Pol

1700

510

7.25

HPLC H2O

1700

12325

11

Total Volume

1700

18700

  • Add 11 ul to each well of a hard shell, full skirt plate. Seal with bubble strips and store in refrigerator until needed label “NovaSeq4 PCR”. (If doing manually, one needs 2 ul of template and 2 ul of the primers).

Run on Thermocycler Program GSAF36:

Temp C

Cycles

Time

95*

1X

3:00*

98

36X

0:30

62

36X

0:30

72

36X

0:30

72

1X

5:00

4

1X

0:00

MagBead Cleanup:

Some plates were cleaned up using the Nimbus platform protocol “AxyPrep MagBead PCR1 No MM”

Manually, it was done:

  • Equilibrate Beads to room Temperature

  • Add 24 ul of MagBeads to each well and 15 ul of replicate to same well of replicate

  • Pipette mix up and down 10 times.

  • Incubate at RT for 5 minutes

  • Secure plate on magnet plate; incubate at RT for 5 minutes (until wells are clear)

  • Remove 65 ul from each well; keep tips to left or right depending on the column to avoid bead pellet.

  • Add 100 ul Fresh 80% EtOH to each well. Incubate 30 seconds. Remove 100 ul from each well

  • Add 100 ul Fresh 80% EtOH to each well. Incubate 30 seconds. Remove 100 ul from each well

  • Reaspirate from each well to assure maximum EtOH removal

  • Allow plate to air dry for 7 minutes.

  • Remove sample plate from magnet plate.

  • Add 40 ul TE; pipette mix 10+ times. Incubate 2 minutes at RT.

  • Place sample plate back on magnet for 5 minutes or until all wells are cleared.

  • Transfer 40 ul to labeled transparent plate (Plate name_PCR_MIDs)

qPCR NovaSeq4_Plate1

  • Make 1:1000 dilutions of column 3 from the PCR plates by adding 1 ul to 999 ul TE in a deep well plate:

 

1

2

3

4

5

6

7

8

9

10

11

12

A

4AH1_16S

4AH1_ITS

4AH2_16S

4AH2_ITS

4PA1_16S

4PA1_ITS

4PA2_16S

4PA2_ITS

 

NTC

NTC

NTC

B

4AH1_16S

4AH1_ITS

4AH2_16S

4AH2_ITS

4PA1_16S

4PA1_ITS

4PA2_16S

4PA2_ITS

 

0.0002 pM Std

0.0002 pM Std

0.0002 pM Std

C

4AH1_16S

4AH1_ITS

4AH2_16S

4AH2_ITS

4PA1_16S

4PA1_ITS

4PA2_16S

4PA2_ITS

 

0.002 pM Std

0.002 pM Std

0.002 pM Std

D

4AH1_16S

4AH1_ITS

4AH2_16S

4AH2_ITS

4PA1_16S

4PA1_ITS

4PA2_16S

4PA2_ITS

 

0.02 pM Std

0.02 pM Std

0.02 pM Std

E

4AH1_16S

4AH1_ITS

4AH2_16S

4AH2_ITS

4PA1_16S

4PA1_ITS

4PA2_16S

4PA2_ITS

 

0.2 pM Std

0.2 pM Std

0.2 pM Std

F

4AH1_16S

4AH1_ITS

4AH2_16S

4AH2_ITS

4PA1_16S

4PA1_ITS

4PA2_16S

4PA2_ITS

 

2 pM Std

2 pM Std

2 pM Std

G

4AH1_16S

4AH1_ITS

4AH2_16S

4AH2_ITS

4PA1_16S

4PA1_ITS

4PA2_16S

4PA2_ITS

 

20 pM Std

20 pM Std

20 pM Std

H

4AH1_16S

4AH1_ITS

4AH2_16S

4AH2_ITS

4PA1_16S

4PA1_ITS

4PA2_16S

4PA2_ITS

  • Add 16 ul of Illumina Library Quantification MasterMix to each well:

ul/rxn

Reagent

# of rxns

ul needed

10 ul

KAPA SYBR FAST qPCR MM (2X)

110

1100

2 ul

Primer Premix (10X)

110

220

4 ul

Ultra Pure Water

110

440

16 ul

Total Volume

110

1760

  • Add 4 ul of template, pool, or standards to each well:

 

1

2

3

4

5

6

7

8

9

10

11

12

A

4AH1_16S

4AH1_ITS

4AH2_16S

4AH2_ITS

4PA1_16S

4PA1_ITS

4PA2_16S

4PA2_ITS

 

NTC

NTC

NTC

B

4AH1_16S

4AH1_ITS

4AH2_16S

4AH2_ITS

4PA1_16S

4PA1_ITS

4PA2_16S

4PA2_ITS

 

0.0002 pM Std

0.0002 pM Std

0.0002 pM Std

C

4AH1_16S

4AH1_ITS

4AH2_16S

4AH2_ITS

4PA1_16S

4PA1_ITS

4PA2_16S

4PA2_ITS

 

0.002 pM Std

0.002 pM Std

0.002 pM Std

D

4AH1_16S

4AH1_ITS

4AH2_16S

4AH2_ITS

4PA1_16S

4PA1_ITS

4PA2_16S

4PA2_ITS

 

0.02 pM Std

0.02 pM Std

0.02 pM Std

E

4AH1_16S

4AH1_ITS

4AH2_16S

4AH2_ITS

4PA1_16S

4PA1_ITS

4PA2_16S

4PA2_ITS

 

0.2 pM Std

0.2 pM Std

0.2 pM Std

F

4AH1_16S

4AH1_ITS

4AH2_16S

4AH2_ITS

4PA1_16S

4PA1_ITS

4PA2_16S

4PA2_ITS

 

2 pM Std

2 pM Std

2 pM Std

G

4AH1_16S

4AH1_ITS

4AH2_16S

4AH2_ITS

4PA1_16S

4PA1_ITS

4PA2_16S

4PA2_ITS

 

20 pM Std

20 pM Std

20 pM Std

H

4AH1_16S

4AH1_ITS

4AH2_16S

4AH2_ITS

4PA1_16S

4PA1_ITS

4PA2_16S

4PA2_ITS

 

 

 

 

Results:

Average results for the following plates (column 3):

4AH1_16S: 11.86 nanomoles

4AH1_ITS: 15.74 nanomoles

4AH2_16S: 36.27 nanomoles

4AH2_ITS: 43.5 nanomoles

4PA1_16S: 4.72 nanomoles

4PA1_ITS: 22.76 nanomoles

4PA2_16S: 8.58 nanomoles

4PA2_ITS: 84.66 nanomoles

Results from the first qPCR plate look good. We will continue by checking one pooled plate on the iSeq for further validation. Full qPCR results are below:

MasterMix (make for 16 plates in 50mL conical tube)

ul/rxn

Reagent

# of rxns

ul needed

3

5X Kapa HiFi Buffer

1700

5100

0.45

10M dNTPs

1700

765

0.3

Kapa HiFi HotStart DNA Pol

1700

510

7.25

HPLC H2O

1700

12325

11

Total Volume

1700

18700

  • Add 11 ul to each well of a hard shell, full skirt plate. Seal with bubble strips and store in refrigerator until needed labeled “NovaSeq4 PCR”. (If doing manually, one needs 2 ul of template and 2 ul of the primers).

Run on Thermocycler Program GSAF36:

Temp C

Cycles

Time

95*

1X

3:00*

98

36X

0:30

62

36X

0:30

72

36X

0:30

72

1X

5:00

4

1X

0:00

MagBead Cleanup:

Some plates were cleaned up using the Nimbus platform protocol “AxyPrep MagBead PCR1 No MM”

Manually, it was done:

  • Equilibrate Beads to room Temperature

  • Add 24 ul of MagBeads to each well and 15 ul of replicate to same well of replicate

  • Pipette mix up and down 10 times.

  • Incubate at RT for 5 minutes

  • Secure plate on magnet plate; incubate at RT for 5 minutes (until wells are clear)

  • Remove 65 ul from each well; keep tips to left or right depending on the column to avoid bead pellet.

  • Add 100 ul Fresh 80% EtOH to each well. Incubate 30 seconds. Remove 100 ul from each well

  • Add 100 ul Fresh 80% EtOH to each well. Incubate 30 seconds. Remove 100 ul from each well

  • Reaspirate from each well to assure maximum EtOH removal

  • Allow plate to air dry for 7 minutes.

  • Remove sample plate from magnet plate.

  • Add 40 ul TE; pipette mix 10+ times. Incubate 2 minutes at RT.

  • Place sample plate back on magnet for 5 minutes or until all wells are cleared.

  • Transfer 40 ul to labeled transparent plate (Plate name_PCR_MIDs)

qPCR NovaSeq4_Plate2

  • Make 1:1000 dilutions of column 3 from the PCR plates by adding 1 ul to 999 ul TE in a deep well plate:

 

1

2

3

4

5

6

7

8

9

10

11

12

A

4PA3_16S

4PA3_ITS

4PA4_16s

4PA4_ITS

4PA5_16S

4PA5_ITS

4PA6_16S

4PA6_ITS

NTC

B

4PA3_16S

4PA3_ITS

4PA4_16s

4PA4_ITS

4PA5_16S

4PA5_ITS

4PA6_16S

4PA6_ITS

04.0002 pM Std

0.0002 pM Std

C

4PA3_16S

4PA3_ITS

4PA4_16s

4PA4_ITS

4PA5_16S

4PA5_ITS

4PA6_16S

4PA6_ITS

0.002 pM Std

0.002 pM Std

D

4PA3_16S

4PA3_ITS

4PA4_16s

4PA4_ITS

4PA5_16S

4PA5_ITS

4PA6_16S

4PA6_ITS

0.02 pM Std

0.02 pM Std

E

4PA3_16S

4PA3_ITS

4PA4_16s

4PA4_ITS

4PA5_16S

4PA5_ITS

4PA6_16S

4PA6_ITS

0.2 pM Std

0.2 pM Std

F

4PA3_16S

4PA3_ITS

4PA4_16s

4PA4_ITS

4PA5_16S

4PA5_ITS

4PA6_16S

4PA6_ITS

2 pM Std

2 pM Std

G

4PA3_16S

4PA3_ITS

4PA4_16s

4PA4_ITS

4PA5_16S

4PA5_ITS

4PA6_16S

4PA6_ITS

20 pM Std

20 pM Std

H

4PA3_16S

4PA3_ITS

4PA4_16s

4PA4_ITS

4PA5_16S

4PA5_ITS

4PA6_16S

4PA6_ITS

  • Add 16 ul of Illumina Library Quantification MasterMix to each well:

ul/rxn

Reagent

# of rxns

ul needed

10 ul

KAPA SYBR FAST qPCR MM (2X)

100

1000

2 ul

Primer Premix (10X)

100

200

4 ul

Ultra Pure Water

100

400

16 ul

Total Volume

100

1600

  • Add 4 ul of template, pool, or standards to each well:

 

1

2

3

4

5

6

7

8

9

10

11

12

A

4PA3_16S

4PA3_ITS

4PA4_16s

4PA4_ITS

4PA5_16S

4PA5_ITS

4PA6_16S

4PA6_ITS

 

NTC

NTC

NTC

B

4PA3_16S

4PA3_ITS

4PA4_16s

4PA4_ITS

4PA5_16S

4PA5_ITS

4PA6_16S

4PA6_ITS

 

0.0002 pM Std

0.0002 pM Std

0.0002 pM Std

C

4PA3_16S

4PA3_ITS

4PA4_16s

4PA4_ITS

4PA5_16S

4PA5_ITS

4PA6_16S

4PA6_ITS

 

0.002 pM Std

0.002 pM Std

0.002 pM Std

D

4PA3_16S

4PA3_ITS

4PA4_16s

4PA4_ITS

4PA5_16S

4PA5_ITS

4PA6_16S

4PA6_ITS

 

0.02 pM Std

0.02 pM Std

0.02 pM Std

E

4PA3_16S

4PA3_ITS

4PA4_16s

4PA4_ITS

4PA5_16S

4PA5_ITS

4PA6_16S

4PA6_ITS

 

0.2 pM Std

0.2 pM Std

0.2 pM Std

F

4PA3_16S

4PA3_ITS

4PA4_16s

4PA4_ITS

4PA5_16S

4PA5_ITS

4PA6_16S

4PA6_ITS

 

2 pM Std

2 pM Std

2 pM Std

G

4PA3_16S

4PA3_ITS

4PA4_16s

4PA4_ITS

4PA5_16S

4PA5_ITS

4PA6_16S

4PA6_ITS

 

20 pM Std

20 pM Std

20 pM Std

H

4PA3_16S

4PA3_ITS

4PA4_16s

4PA4_ITS

4PA5_16S

4PA5_ITS

4PA6_16S

4PA6_ITS

 

 

 

 

Results:

Average results for the following plates (column 3):

4PA3_16S: 4.04 nanomoles

4PA3_ITS: 46.07 nanomoles

4PA4_16S: 71.0 nanomoles

4PA4_ITS: 68.5 nanomoles

4PA5_16S: 10.26 nanomoles

4PA5_ITS: 41.22 nanomoles

4PA6_16S: 11.57 nanomoles

4PA6_ITS: 44.52 nanomoles

Quantities look good for sequencing. The full result report can be viewed below:

MasterMix (make for 12 plates in 15mL conical tube)

ul/rxn

Reagent

# of rxns

ul needed

3

5X Kapa HiFi Buffer

1210

3630

0.45

10M dNTPs

1210

544.5

0.3

Kapa HiFi HotStart DNA Pol

1210

363

7.25

HPLC H2O

1210

8772.5

11

Total Volume

1210

13310

  • Add 11 ul to each well of a hard shell, full skirt plate. Seal with bubble strips and store in refrigerator until needed labeled “NovaSeq4 PCR”. (If doing manually, one needs 2 ul of template and 2 ul of the primers).

Run on Thermocycler Program GSAF36:

Temp C

Cycles

Time

95*

1X

3:00*

98

36X

0:30

62

36X

0:30

72

36X

0:30

72

1X

5:00

4

1X

0:00

MagBead Cleanup:

Some plates were cleaned up using the Nimbus platform protocol “AxyPrep MagBead PCR1 No MM”

Manually, it was done:

  • Equilibrate Beads to room Temperature

  • Add 24 ul of MagBeads to each well and 15 ul of replicate to same well of replicate

  • Pipette mix up and down 10 times.

  • Incubate at RT for 5 minutes

  • Secure plate on magnet plate; incubate at RT for 5 minutes (until wells are clear)

  • Remove 65 ul from each well; keep tips to left or right depending on the column to avoid bead pellet.

  • Add 100 ul Fresh 80% EtOH to each well. Incubate 30 seconds. Remove 100 ul from each well

  • Add 100 ul Fresh 80% EtOH to each well. Incubate 30 seconds. Remove 100 ul from each well

  • Reaspirate from each well to assure maximum EtOH removal

  • Allow plate to air dry for 7 minutes.

  • Remove sample plate from magnet plate.

  • Add 40 ul TE; pipette mix 10+ times. Incubate 2 minutes at RT.

  • Place sample plate back on magnet for 5 minutes or until all wells are cleared.

  • Transfer 40 ul to labeled transparent plate (Plate name_PCR_MIDs)

qPCR NovaSeq4_Plate3

  • Make 1:1000 dilutions of column 3 from the PCR plates by adding 1 ul to 999 ul TE in a deep well plate:

 

1

2

3

4

5

6

7

8

9

10

11

12

A

4MR1_16S

4MR1_ITS

 4MR2_16S

4MR2_ITS

4SC1_16S

4SC1_ITS

4SC2_16S

4SC2_ITS

NTC

B

4MR1_16S

4MR1_ITS

 4MR2_16S

4MR2_ITS

4SC1_16S

4SC1_ITS

4SC2_16S

4SC2_ITS

04.0002 pM Std

0.0002 pM Std

C

4MR1_16S

4MR1_ITS

 4MR2_16S

4MR2_ITS

4SC1_16S

4SC1_ITS

4SC2_16S

4SC2_ITS

0.002 pM Std

0.002 pM Std

D

4MR1_16S

4MR1_ITS

 4MR2_16S

4MR2_ITS

4SC1_16S

4SC1_ITS

4SC2_16S

4SC2_ITS

0.02 pM Std

0.02 pM Std

E

4MR1_16S

4MR1_ITS

 4MR2_16S

4MR2_ITS

4SC1_16S

4SC1_ITS

4SC2_16S

4SC2_ITS

0.2 pM Std

0.2 pM Std

F

4MR1_16S

4MR1_ITS

 4MR2_16S

4MR2_ITS

4SC1_16S

4SC1_ITS

4SC2_16S

4SC2_ITS

2 pM Std

2 pM Std

G

4MR1_16S

4MR1_ITS

 4MR2_16S

4MR2_ITS

4SC1_16S

4SC1_ITS

4SC2_16S

4SC2_ITS

20 pM Std

20 pM Std

H

4MR1_16S

4MR1_ITS

 4MR2_16S

4MR2_ITS

4SC1_16S

4SC1_ITS

4SC2_16S

4SC2_ITS

  • Add 16 ul of Illumina Library Quantification MasterMix to each well:

ul/rxn

Reagent

# of rxns

ul needed

10 ul

KAPA SYBR FAST qPCR MM (2X)

100

1000

2 ul

Primer Premix (10X)

100

200

4 ul

Ultra Pure Water

100

400

16 ul

Total Volume

100

1600

  • Add 4 ul of template, pool, or standards to each well:

 

1

2

3

4

5

6

7

8

9

10

11

12

A

4MR1_16S

4MR1_ITS

 4MR2_16S

4MR2_ITS

4SC1_16S

4SC1_ITS

4SC2_16S

4SC2_ITS

 

NTC

NTC

NTC

B

4MR1_16S

4MR1_ITS

 4MR2_16S

4MR2_ITS

4SC1_16S

4SC1_ITS

4SC2_16S

4SC2_ITS

 

0.0002 pM Std

0.0002 pM Std

0.0002 pM Std

C

4MR1_16S

4MR1_ITS

 4MR2_16S

4MR2_ITS

4SC1_16S

4SC1_ITS

4SC2_16S

4SC2_ITS

 

0.002 pM Std

0.002 pM Std

0.002 pM Std

D

4MR1_16S

4MR1_ITS

 4MR2_16S

4MR2_ITS

4SC1_16S

4SC1_ITS

4SC2_16S

4SC2_ITS

 

0.02 pM Std

0.02 pM Std

0.02 pM Std

E

4MR1_16S

4MR1_ITS

 4MR2_16S

4MR2_ITS

4SC1_16S

4SC1_ITS

4SC2_16S

4SC2_ITS

 

0.2 pM Std

0.2 pM Std

0.2 pM Std

F

4MR1_16S

4MR1_ITS

 4MR2_16S

4MR2_ITS

4SC1_16S

4SC1_ITS

4SC2_16S

4SC2_ITS

 

2 pM Std

2 pM Std

2 pM Std

G

4MR1_16S

4MR1_ITS

 4MR2_16S

4MR2_ITS

4SC1_16S

4SC1_ITS

4SC2_16S

4SC2_ITS

 

20 pM Std

20 pM Std

20 pM Std

H

4MR1_16S

4MR1_ITS

 4MR2_16S

4MR2_ITS

4SC1_16S

4SC1_ITS

4SC2_16S

4SC2_ITS

 

 

 

 

Results:

Average results for the following plates (column 3):

4MR1_16S: 92.23 nanomoles

4MR1_ITS: 53.47 nanomoles

4MR2_16S: 105.34 nanomoles

4MR2_ITS: 66.71 nanomoles

4SC1_16S: 46.64 nanomoles

4SC1_ITS: 47.77 nanomoles

4SC2_16S: 65.97 nanomoles

4SC2_ITS: 55.69 nanomoles

Quantities look good for sequencing. The full result report can be viewed below:

MasterMix (make for 24 plates in 50mL conical tube)

ul/rxn

Reagent

# of rxns

ul needed

3

5X Kapa HiFi Buffer

2500

7500

0.45

10M dNTPs

2500

1125

0.3

Kapa HiFi HotStart DNA Pol

2500

750

7.25

HPLC H2O

2500

18125

11

Total Volume

2500

27500

  • Add 11 ul to each well of a hard shell, full skirt plate. Seal with bubble strips and store in refrigerator until needed label “NovaSeq4 PCR”. (If doing manually, one needs 2 ul of template and 2 ul of the primers).

Run on Thermocycler Program GSAF36:

Temp C

Cycles

Time

95*

1X

3:00*

98

36X

0:30

62

36X

0:30

72

36X

0:30

72

1X

5:00

4

1X

0:00

MagBead Cleanup:

Some plates were cleaned up using the Nimbus platform protocol “AxyPrep MagBead PCR1 No MM”

Manually, it was done:

  • Equilibrate Beads to room Temperature

  • Add 24 ul of MagBeads to each well and 15 ul of replicate to same well of replicate

  • Pipette mix up and down 10 times.

  • Incubate at RT for 5 minutes

  • Secure plate on magnet plate; incubate at RT for 5 minutes (until wells are clear)

  • Remove 65 ul from each well; keep tips to left or right depending on the column to avoid bead pellet.

  • Add 100 ul Fresh 80% EtOH to each well. Incubate 30 seconds. Remove 100 ul from each well

  • Add 100 ul Fresh 80% EtOH to each well. Incubate 30 seconds. Remove 100 ul from each well

  • Reaspirate from each well to assure maximum EtOH removal

  • Allow plate to air dry for 7 minutes.

  • Remove sample plate from magnet plate.

  • Add 40 ul TE; pipette mix 10+ times. Incubate 2 minutes at RT.

  • Place sample plate back on magnet for 5 minutes or until all wells are cleared.

  • Transfer 40 ul to labeled transparent plate (Plate name_PCR_MIDs)

qPCR NovaSeq4_Plate4

  • Make 1:1000 dilutions of column 3 from the PCR plates by adding 1 ul to 999 ul TE in a deep well plate:

 

1

2

3

4

5

6

7

8

9

10

11

12

A

4LVD1_16S

4LVD1_ITS

4LVD2_16S

4LVD2_ITS

4LVD3_16S

4LVD3_ITS

 

NTC

NTC

NTC

B

4LVD1_16S

4LVD1_ITS

4LVD2_16S

4LVD2_ITS

4LVD3_16S

4LVD3_ITS

 

0.0002 pM Std

0.0002 pM Std

0.0002 pM Std

C

4LVD1_16S

4LVD1_ITS

4LVD2_16S

4LVD2_ITS

4LVD3_16S

4LVD3_ITS

 

0.002 pM Std

0.002 pM Std

0.002 pM Std

D

4LVD1_16S

4LVD1_ITS

4LVD2_16S

4LVD2_ITS

4LVD3_16S

4LVD3_ITS

 

0.02 pM Std

0.02 pM Std

0.02 pM Std

E

4LVD1_16S

4LVD1_ITS

4LVD2_16S

4LVD2_ITS

4LVD3_16S

4LVD3_ITS

 

0.2 pM Std

0.2 pM Std

0.2 pM Std

F

4LVD1_16S

4LVD1_ITS

4LVD2_16S

4LVD2_ITS

4LVD3_16S

4LVD3_ITS

 

2 pM Std

2 pM Std

2 pM Std

G

4LVD1_16S

4LVD1_ITS

4LVD2_16S

4LVD2_ITS

4LVD3_16S

4LVD3_ITS

 

20 pM Std

20 pM Std

20 pM Std

H

4LVD1_16S

4LVD1_ITS

4LVD2_16S

4LVD2_ITS

4LVD3_16S

4LVD3_ITS

  • Add 16 ul of Illumina Library Quantification MasterMix to each well:

ul/rxn

Reagent

# of rxns

ul needed

10 ul

KAPA SYBR FAST qPCR MM (2X)

80

800

2 ul

Primer Premix (10X)

80

160

4 ul

Ultra Pure Water

80

320

16 ul

Total Volume

80

1280

  • Add 4 ul of template, pool, or standards to each well:

 

1

2

3

4

5

6

7

8

9

10

11

12

A

4LVD1_16S

4LVD1_ITS

4LVD2_16S

4LVD2_ITS

4LVD3_16S

4LVD3_ITS

 

NTC

NTC

NTC

B

4LVD1_16S

4LVD1_ITS

4LVD2_16S

4LVD2_ITS

4LVD3_16S

4LVD3_ITS

 

0.0002 pM Std

0.0002 pM Std

0.0002 pM Std

C

4LVD1_16S

4LVD1_ITS

4LVD2_16S

4LVD2_ITS

4LVD3_16S

4LVD3_ITS

 

0.002 pM Std

0.002 pM Std

0.002 pM Std

D

4LVD1_16S

4LVD1_ITS

4LVD2_16S

4LVD2_ITS

4LVD3_16S

4LVD3_ITS

 

0.02 pM Std

0.02 pM Std

0.02 pM Std

E

4LVD1_16S

4LVD1_ITS

4LVD2_16S

4LVD2_ITS

4LVD3_16S

4LVD3_ITS

 

0.2 pM Std

0.2 pM Std

0.2 pM Std

F

4LVD1_16S

4LVD1_ITS

4LVD2_16S

4LVD2_ITS

4LVD3_16S

4LVD3_ITS

 

2 pM Std

2 pM Std

2 pM Std

G

4LVD1_16S

4LVD1_ITS

4LVD2_16S

4LVD2_ITS

4LVD3_16S

4LVD3_ITS

 

20 pM Std

20 pM Std

20 pM Std

H

4LVD1_16S

4LVD1_ITS

4LVD2_16S

4LVD2_ITS

4LVD3_16S

4LVD3_ITS

 

 

 

 

Results:

Average results for the following plates (column 3):

4LVD1_16S: 112.54 nanomoles

4LVD1_ITS: 24.71 nanomoles

4LVD2_16S: 95.57 nanomoles

4LVD2_ITS: 34.28 nanomoles

4LVD3_16S: 112.47 nanomoles

4LVD3_ITS: 101.03 nanomoles

Quantities look good for sequencing. The full result report can be viewed below:

qPCR NovaSeq4_Plate5

  • Make 1:1000 dilutions of column 3 from the PCR plates by adding 1 ul to 999 ul TE in a deep well plate:

  • Use other half of NS4_Plate 4 dilution plate to do NS4_Plate5 dilution plate.

 

1

2

3

4

5

6

7

8

9

10

11

12

A

______

______

______

______

______

______

4FB1_16S

4FB1_ITS

 4FB2_16S

4FB2_ITS

4FB3_16S

4FB3_ITS

B

______

______

______

______

______

______

4FB1_16S

4FB1_ITS

 4FB2_16S

4FB2_ITS

4FB3_16S

4FB3_ITS

C

______

______

______

______

______

______

4FB1_16S

4FB1_ITS

 4FB2_16S

4FB2_ITS

4FB3_16S

4FB3_ITS

D

______

______

______

______

______

______

4FB1_16S

4FB1_ITS

 4FB2_16S

4FB2_ITS

4FB3_16S

4FB3_ITS

E

______

______

______

______

______

______

4FB1_16S

4FB1_ITS

 4FB2_16S

4FB2_ITS

4FB3_16S

4FB3_ITS

F

______

______

______

______

______

______

4FB1_16S

4FB1_ITS

 4FB2_16S

4FB2_ITS

4FB3_16S

4FB3_ITS

G

______

______

______

______

______

______

4FB1_16S

4FB1_ITS

 4FB2_16S

4FB2_ITS

4FB3_16S

4FB3_ITS

H

______

______

______

______

______

______

4FB1_16S

4FB1_ITS

 4FB2_16S

4FB2_ITS

4FB3_16S

4FB3_ITS

  • Add 16 ul of Illumina Library Quantification MasterMix to each well:

ul/rxn

Reagent

# of rxns

ul needed

10 ul

KAPA SYBR FAST qPCR MM (2X)

80

800

2 ul

Primer Premix (10X)

80

160

4 ul

Ultra Pure Water

80

320

16 ul

Total Volume

80

1280

  • Add 4 ul of template, pool, or standards to each well:

 

1

2

3

4

5

6

7

8

9

10

11

12

A

4FB1_16S

4FB1_ITS

 4FB2_16S

4FB2_ITS

4FB3_16S

4FB3_ITS

 

NTC

NTC

NTC

B

4FB1_16S

4FB1_ITS

 4FB2_16S

4FB2_ITS

4FB3_16S

4FB3_ITS

 

0.0002 pM Std

0.0002 pM Std

0.0002 pM Std

C

4FB1_16S

4FB1_ITS

 4FB2_16S

4FB2_ITS

4FB3_16S

4FB3_ITS

 

0.002 pM Std

0.002 pM Std

0.002 pM Std

D

4FB1_16S

4FB1_ITS

 4FB2_16S

4FB2_ITS

4FB3_16S

4FB3_ITS

 

0.02 pM Std

0.02 pM Std

0.02 pM Std

E

4FB1_16S

4FB1_ITS

 4FB2_16S

4FB2_ITS

4FB3_16S

4FB3_ITS

 

0.2 pM Std

0.2 pM Std

0.2 pM Std

F

4FB1_16S

4FB1_ITS

 4FB2_16S

4FB2_ITS

4FB3_16S

4FB3_ITS

 

2 pM Std

2 pM Std

2 pM Std

G

4FB1_16S

4FB1_ITS

 4FB2_16S

4FB2_ITS

4FB3_16S

4FB3_ITS

 

20 pM Std

20 pM Std

20 pM Std

H

4FB1_16S

4FB1_ITS

 4FB2_16S

4FB2_ITS

4FB3_16S

4FB3_ITS

 

 

 

 

Results:

Average results for the following plates (column 3):

4FB1_16S:

4FB1_ITS:

4FB2_16S:

4FB2_ITS:

4FB3_16S:

4FB3_ITS:

  • No labels