Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Quantify DNAs on Synergy HTX Plate Reader:

Normalize DNAs on Nimbus:

16S Library Prep:

NEED TO ADJUST #OF RXNS!!!!

Add 12 ul Master mix to each well:

ul/rxn

Reagent

# of rxns

ul needed

3

5X Phusion HF Buffer

24

120

0.45

10M dNTPs

24

18

1

0.0001ng/ul 16S Synthgene_GR

0.3

Kapa HiFi HotStart DNA Pol

24

12

2.25

HPLC H2O

24

210

7

Total Volume

24

360

Add 6 ul 0.25 uM paired primers ____________________

Add 2 ul of appropriate gDNA to each well

Run on Thermocycler Program 35GSAF1:

Temp C

Cycles

Time

95*

1X

3:00

98

15X

0:30

62

15X

0:30

72

15X

0:30

72

1X

5:00

4

1X

0:00

Pool Duplicates

Purify samples using modified manual AxyPrep MagBead PCR Clean-Up (GSAF uses AmpPure XP):

AmpPure XP PCR cleanup and AxyPrep MagBead have the exact same stock protocol!

Equilibrate Beads to room Temperature

Add 24 ul of MagBeads to each well; Pipette mix up and down 10 times.

Incubate at RT for 5 minutes

Secure plate on magnet plate; incubate at RT for 5 minutes (until wells are clear)

Remove 54 ul from each well; keep tips to left or right depending on the column to avoid bead pellet.

Add 100 ul Fresh 80% EtOH to each well. Incubate 30 seconds. Remove 100 ul from each well.

Add 100 ul Fresh 80% EtOH to each well. Incubate 30 seconds. Remove 100 ul from each well.

Allow plate to air dry for 7 minutes.

Remove sample plate from magnet plate.

Add 15 ul TE per GSAF protocol; pipette mix 10+ times

Incubate at RT for 2 minutes

Place sample plate back on magnet for 5 minutes or until all wells are cleared.

Prepare next MasterMix while sample plate is on the magnet plate.

Add 20 ul FlowCell MasterMix to new plate:

ul/rxn

Reagent

# of rxns

ul needed

3

5X Phusion HF Buffer

8

60

0.45

10M dNTPs

8

9

0.3

Kapa HiFi HotStart DNA Pol

8

6

0.5 ul

10 uM F and R FlowCell Primers

8

10

0.75

HPLC H2O

8

115

5

Total Volume

8

600

Transfer 10 ul from plate on magnet plate to new strip tubes.

Run on Thermocycler Program 35GSAF2:

Temp C

Cycles

Time

95*

1X

3:00

98

19X

0:30

55*

19X

0:30

72

19X

0:30

72

1X

5:00

4

1X

0:00

Purify samples using GSAF’s second modified MagBead protocol:

Equilibrate Beads to room Temperature

Add 15 ul H2O to each sample

Add 24 ul (0.8 x 60 ul) of MagBeads to each well; Pipette mix up and down 10 times

Incubate at RT for 5 minutes

Secure plate on magnet plate; incubate at RT for 5 minutes (until wells are clear)

Remove 54 ul from each well; keep tips to left or right depending on the column to avoid bead pellet.

Add 100 ul Fresh 80% EtOH to each well. Incubate 30 seconds. Remove 100 ul from each well.

Add 100 ul Fresh 80% EtOH to each well. Incubate 30 seconds. Remove 100 ul from each well.

Allow plate to air dry for 7 minutes.

Remove sample plate from magnet plate.

Add 23 ul TE per GSAF protocol; pipette mix 10 times

Incubate at RT for 2 minutes

Place sample plate back on magnet for 5 minutes or until all wells are cleared.

Transfer 20 ul to a clean PCR plate.

  • No labels